Vontron Reverse Osmosis Membrane LP11-4040
Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.
- Estimated Delivery : Up to 4 business days
Vontron ULP11‑4040 RO Membrane – Ultra‑Low‑Pressure 4″×40″
The Vontron ULP11‑4040 RO Membrane is an ultra-low-pressure (ULP) reverse osmosis element designed for municipal water, surface water, and low‑salinity applications. This high-performance RO membrane reduces energy costs while maintaining excellent water quality. With a standard 4″×40″ size, it fits most RO systems for domestic and light industrial use.
Key Features of Vontron ULP11‑4040 RO Membrane
- Ultra‑low pressure operation minimizes pump energy requirements.
- Typical permeate output of 2,700 GPD with 97.5–99% salt rejection.
- Standard 4″×40″ size ensures easy integration.
- Suitable for feedwater TDS up to 2,000 ppm.
- Robust operating limits: max 600 psi pressure, 45 °C temperature.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | ULP11‑4040 |
| Active Membrane Area | ~90 ft² (≈8.4 m²) |
| Typical Permeate Flow | ~2,700 GPD (~10.2 m³/day) under test conditions |
| Stable Rejection Rate | 98.0% (typical) |
| Minimum Rejection Rate | 97.5% |
| Testing Conditions | Test Pressure: 150 psi (1.03 MPa) Test Solution: 1,500 ppm NaCl, 25 °C, pH 7.5 Recovery Rate: 15% (single element) |
| Max Feed Operating Pressure | 600 psi (~4.14 MPa) |
| Max Feed Flow | ~16 gpm (~3.6 m³/hr) for 4040 size |
| Max Feed Temperature | 45 °C |
| Max Feed SDI | ≤ 5 |
| Residual Chlorine in Feed | < 0.1 ppm |
| pH Range (Continuous Operation) | 3 to 10 |
| pH Range (Cleaning) | 2 to 12 |
| Max Pressure Drop (single element) | 15 psi (~0.1 MPa) |
| Physical Dimensions | Length ≈ 1016 mm (40″) Outer Diameter ≈ 99.7 mm (3.9″) |
Why Choose the Vontron ULP11‑4040 RO Membrane?
Because it blends compact size with high capacity and efficiency, this membrane is a smart upgrade for systems treating municipal or low‑brackish water where energy cost and pump size matter. Its ultra-low-pressure design cuts operating cost and simplifies system design. Additionally, its proven brand and performance make it reliable for commercial installations.
Benefits of Using Vontron ULP11‑4040
This RO membrane ensures reliable, high‑quality water for domestic, commercial, and light industrial systems. It reduces operational costs, fits standard housings, and guarantees long-term performance. Perfect for retrofits and new installations alike.
Installation & Maintenance Tips
- Ensure pre‑treatment: feed silt density index (SDI) ≤ 5; free chlorine in feed < 0.1 ppm.
- On initial startup, flush new element: 15‑25 minutes at low pressure, then 60‑90 minutes at design pressure. Discard the first hour permeate.
- Monitor permeate flow and rejection: declining performance may indicate fouling, scaling, or damage.
- Clean according to manufacturer guidelines, observe pH limits (cleaning 2‑12).
- Store spares wet or in a protective solution (1% sodium bisulfite) if the system is idle.
| Weight | 3,85 kg |
|---|---|
| Dimensions | 105 × 15 × 15 cm |